Perkins Diesel Generator adopts UK Perkins Engines and Stamford/Leory Somer Alternators to provide reliable output for customers
Perkins Super silent Generator has unique excellence in soundproof function. And its noise level is only 60--65dB at distance of 7m.
Specification of power diesel generator set.
1)Output range:18kVA--220kVA
2)Sound level:60--65dB at 7 meters
3)Sound attenuated enclosure: special noise elimination setting restrains the machinery noise and the unit has perfect all-weather service property and the outside steel material features preferable corrosion prevention capability.
4)Water-cooled
5)We can design and offer above 60-hours running base tank.
6)Key start/Auto Start
7)Sound-proof/weather-proof canopy is optional
8)220V/127V,440V/254V,60Hz,1800RPM,0.8PF, AC three phase and 4 wires
9)Frequency: 60Hz
10)Frequency at stable state:<0.5%
11)Frequency deviation at instantaneous state:d+10%
12)Frequency return time:d3s
13)Voltage deviation at stable state : d ± 1%
14)Voltage deviation at instantaneous state:d+20%
15)Voltage return time:d4s
16)Voltage modulation:d0.3%
17)Standard configuration of power diesel generator set:
a)Engine:UK Perkins Diesel Engines
b)Engine character:water-cooled,in line four-stroke,BYC ASIMCO PB pump injection
c)Alternator: brushless and H class insulation
18)Control System:
a)Automatic alarm system: the unit has the acousto-optics alarm and arrestor for any situation as the start defeat, the water is over temperature, the oil pulls down, over speed, over load and over current
b)Operation display:
i)Unit voltage, tri-phase load current and frequency display
ii)Water temperature, oil pressure display
iii)Fuel level, fuel temperature display
iv)Audible and visual alarm lamps and buzzers
19)Starting system: DC alternator is used to start engine
20)Cooling system: combined cooling water tank fitted to meet the requirement of radiation at ambient temperature 40 centigrade.
60Hz,220V/127V,440V/254V,3Ph,4Wires,1800RPM
MODEL | OUTPUT(kW/kVA) | ENGINE | ALTERNATOR | ||||
PRIME | STANDBY | CONTINUOUS | PRIME | STANDBY | PERKINS | STAMFORD | LEORY SOMER |
P22.5PX/S3 | P25EX/S3 | 14.4/18 | 18/22.5 | 20/25 | 404D-22G | BCI184E | LSA42.2S4 |
P31PX/S3 | P34EX/S3 | 19.6/24.5 | 24.5/31 | 27/34 | 404D-22TG | BCI184F | LSA42.2M6 |
P34PX/S3 | P37EX/S3 | 21.5/27 | 27/34 | 30/37 | 404D-22TAG | BCI184F | LSA42.2M7 |
P50PX/S3 | P55EX/S3 | 32/40 | 40/50 | 44/55 | 1104D-44TG1 | BCI184J | LSA43.2 S15 |
P63PX/S3 | P69EX/S3 | 40/50 | 50/63 | 55/69 | 1104D-44TG1 | UCI224D | LSA43.2 M45 |
P73PX/S3 | P81EX/S3 | 47/59 | 59/73 | 65/81 | 1104D-E44TG1 | UCI224F | LSA43.2 L65 |
P93PX/S3 | P102EX/S3 | 59/74 | 74/93 | 82/102 | 1104D-E44TAG1 | UCI224G | LSA44.2 VS3 |
P113PX/S3 | P124EX/S3 | 72/90 | 90/113 | 99/124 | 1104D-E44TAG2 | UCI274C | LSA44.2 VS45 |
P157PX/S3 | P173EX/S3 | 101/126 | 126/157 | 138/173 | 1106D-E66TAG2 | UCI274E | LSA44.2 S75 |
P168PX/S3 | P184EX/S3 | 107/134 | 134/168 | 147/184 | 1106D-E66TAG3 | UCI274E | LSA44.2 M95 |
P200PX/S3 | P220EX/S3 | 128/160 | 160/200 | 176/220 | 1106D-E66TAG4 | UCI274G | LSA46.2 M3 |